Z2-808A 2-phase Stepper Driver

Z2-808A is used to drive 2-phase hybrid stepper motor 86 type. Its maximum out current is 8.0A (peak). It needs AC20-80V power supply. Input signal frequency can reach over 200KHz. It has 255 different steps with minimum steps 200 and maximum steps 51000. 14 steps are directly selected by DIP switches and others are set by DIP switches.
  • 产品详情
  • 装配尺寸
  • 使用指南
  • 配套产品

Z2-808Ais an all-digital 2 phase stepper driver. It adopts the advanced controlcalculation, no matter how many steps to set, motor current is the accuratesine. The advantages are excellent performance, super stability, low-speed muteand extremely low heat.

255steps for different transmission ratio

Singlepulse, dual pulse

16kinds of output current

11kinds of lock current percentage (0-100%)

16kinds of lock time (0.1-2 seconds)

ENsignal can work as off-line mode or lock mode

Inputsignal can be any value between 5V and 24V

Automaticallyrecord the breaking point when power off

Greatprotection system (undervoltage, over voltage, over current, etc.)


Set steps

Steps for the motorrotating one cycle, 255 different steps, sw1-4 for steps, 14 steps can directlyselect, if need other steps, set sw1-4 to 0000, on=0, off=1

sw1-4

steps

sw1-4

steps

sw1-4

steps

sw1-4

steps

0000

Saved steps

0100

2000

1000

6400

1100

20000

0001

800

0101

3200

1001

8000

1101

25600

0010

1000

0110

4000

1010

10000

1110

40000

0011

1600

0111

5000

1011

12800

1111

Set Operation

Set current

16 different currents,sw5-8 to set, it’s peak

Sw5-8

Current

Sw5-8

Current

Sw5-8

Current

Sw5-8

Current

0000

2.5A

0100

4.3A

1000

5.6A

1100

7.0A

0001

3.0A

0101

4.6A

1001

6.0A

1101

7.3A

0010

3.5A

0110

5.0A

1010

6.3A

1110

7.6A

0011

4.0A

0111

5.3A

1011

6.6A

1111

8.0A

Input signal

3 signals: CP, DIR, EN,signal value 5~24V, single pulse: CP is pulse signal, one pulse is one step,DIR is direction level signal, the signal must be steady before sending CP,dual pulse: CP is positive pulse signal CW, DIR is negative direction pulsesignal CCW, EN is enable signal, when not connect EN, or differential level is0, then driver is enable status, and driver works well, when EN differentiallevel is 1, then driver is non-enable status, and the driver stopes working,non-enable can set as offline or lock mode, factory set is offline mode.


Lock currentpercentage

Whenthe motor does not work, lock current reduces for less consumption and heat. Differentlock percent is available,0%(offline)-10%-20%-30%-40%-50%-60%-70%-80%-90%-100%(full current), default 50%


Lock time

It takes time that pulsesignal stops lock current and make it work, time 0.1s-2.0s, default 1.0s


Indicator lightstatus

Green

Red

Status

Green

Red

Status

On

Off

Normal

On

Slow blink

Less voltage

On

Fast blink

Over current

On

Double blink

Over voltage


Home