Z2-808Ais an all-digital 2 phase stepper driver. It adopts the advanced controlcalculation, no matter how many steps to set, motor current is the accuratesine. The advantages are excellent performance, super stability, low-speed muteand extremely low heat.
255steps for different transmission ratio
Singlepulse, dual pulse
16kinds of output current
11kinds of lock current percentage (0-100%)
16kinds of lock time (0.1-2 seconds)
ENsignal can work as off-line mode or lock mode
Inputsignal can be any value between 5V and 24V
Automaticallyrecord the breaking point when power off
Greatprotection system (undervoltage, over voltage, over current, etc.)
Set steps
Steps for the motorrotating one cycle, 255 different steps, sw1-4 for steps, 14 steps can directlyselect, if need other steps, set sw1-4 to 0000, on=0, off=1
sw1-4 | steps | sw1-4 | steps | sw1-4 | steps | sw1-4 | steps |
0000 | Saved steps | 0100 | 2000 | 1000 | 6400 | 1100 | 20000 |
0001 | 800 | 0101 | 3200 | 1001 | 8000 | 1101 | 25600 |
0010 | 1000 | 0110 | 4000 | 1010 | 10000 | 1110 | 40000 |
0011 | 1600 | 0111 | 5000 | 1011 | 12800 | 1111 | Set Operation |
Set current
16 different currents,sw5-8 to set, it’s peak
Sw5-8 | Current | Sw5-8 | Current | Sw5-8 | Current | Sw5-8 | Current |
0000 | 2.5A | 0100 | 4.3A | 1000 | 5.6A | 1100 | 7.0A |
0001 | 3.0A | 0101 | 4.6A | 1001 | 6.0A | 1101 | 7.3A |
0010 | 3.5A | 0110 | 5.0A | 1010 | 6.3A | 1110 | 7.6A |
0011 | 4.0A | 0111 | 5.3A | 1011 | 6.6A | 1111 | 8.0A |
Input signal
3 signals: CP, DIR, EN,signal value 5~24V, single pulse: CP is pulse signal, one pulse is one step,DIR is direction level signal, the signal must be steady before sending CP,dual pulse: CP is positive pulse signal CW, DIR is negative direction pulsesignal CCW, EN is enable signal, when not connect EN, or differential level is0, then driver is enable status, and driver works well, when EN differentiallevel is 1, then driver is non-enable status, and the driver stopes working,non-enable can set as offline or lock mode, factory set is offline mode.
Lock currentpercentage
Whenthe motor does not work, lock current reduces for less consumption and heat. Differentlock percent is available,0%(offline)-10%-20%-30%-40%-50%-60%-70%-80%-90%-100%(full current), default 50%
Lock time
It takes time that pulsesignal stops lock current and make it work, time 0.1s-2.0s, default 1.0s
Indicator lightstatus
Green | Red | Status | Green | Red | Status |
On | Off | Normal | On | Slow blink | Less voltage |
On | Fast blink | Over current | On | Double blink | Over voltage |